W Series Data Sheet
?
125, 250 Watt AC-DC and DC-DC DIN-Rail Converters
dBμV
PMM 8000 PLUS
Limit: 61204bqp Detector: Peak, conducted Vi+, 6.6.06
EWN2660-0 Ui=110VDC, Io=10A, outputs in parallel configuration
dBμV
PMM 8000 PLUS
Limit: 61204aqp Detector: Average Phase line Filter3 01.09.06
LWN1701-6E Ui=230VAC, Ponom, Schurter-Filter 4A + Drossel 11μH/4A
60
40
20
0
EN 55011 B
60
40
20
0
EN 55022 B
0.2
0.5
1
2
5
10
20 MHz
0.2
0.5
1
2
5
10
20 MHz
Fig. 13a
Conducted emissions of EW models:
Disturbances (peak) at the phase input according to EN 55011,
measured at V i nom and I o nom . (EWN2660- 0)
Fig. 14b
Conducted disturbances (average) of LW models (feature E)
with external filter at phase input according to EN 55011/
55022, at V i = 230 VAC, I o nom (LWN1701-6E).
dBμV/m
50
40
30
20
10
TüV-Divina, ESVS 30:R&S, BBA 9106/UHALP 9107:Schwarzb., QP, 2006-05-29
Testdistance 10 m, EWN2660-0 Ui=110 V, Uo=24 V Io= 2 x 5 A
EN 55011 A
<25 dbμV/m
Fig. 14a and 14b show the conducted emissions smoothed
by an external filter. The standards EN 55011 and 55022
define limits for conducted (quasi)peak and conducted
average emissions. In general the limits for average
emissions are more difficult to meet.
The figure below shows the used external filter configuration
consisting of the inlet filter KMF1.1241.11 (4 A, Schurter
www.schurter.com ) and the decopling choke EPCOS
B82111B0000C018, 11 μH, 4 A, 6 × 20 mm.
Note: This filter allows for connection of an IEC inlet and is
0
30
50
100
200
500
1000 MHz
available with 1 or 2 incorporated fuses.
A similar filter with AMP terminals (6.3 × 20 mm) is also available
Fig. 13b
Radiated emissions of EW models, measured at V i nom , I o nom ,
accord. to EN 55011, antenna 3 m distance, (EWN2660-0)
(Schurter FMLB 5500.2028).
JM007
External EMC Filter for Models with Feature E
L'
Choke
L
An external EMC filter can be connected to the inputs lines of
PE
PE'
PE
the converter. However, a small choke has to be included in
the phase line to avoid interferences between the internal and
external filter, which would cause dramatically increased low
harmonics.
N'
N
dBμV
60
PMM 8000 PLUS
Limit: 61204bqp Detector: Peak Phase Line Filter3 01.09.06
LWN1701-6E Ui=230VAC, Ponom, Schurter-Filter 4A + Drossel 11μH/4A
EN 55022 B
Fig. 15a
External filter to reduce conducted emissions of LW models
with feature E (L1 = L2 = 1.6 mH, Cx = 47 nF,
Cy = 2.2 nF)
40
20
0
0.2
0.5
1
2
5
10
20 MHz
Fig. 14a
Conducted disturbances (peak) of LW models (feature E)
with external filter at phase input according to EN 55011/
55022, at V i = 230 VAC, I o nom (LWN1701-6E).
Fig. 15b
External inlet filter
BCD20020-G Rev AC, 31-Jan-2013
Page 15 of 25
www.power-one.com
相关PDF资料
EX-4502 BOX EXTRUD ALUM 1.57X3.14X6.96"
EX-4523 BOX EXTRUD ALUM 3.18X6.14X9.32"
EX-4543 BOX EXTRUD ALUM 9.32X3.78X3.78"
EX-AR30 SWITCH EXPLOSION PROOF SPDT 15A
EX-XR3 EXP PROOF LIMIT SWITCH SPDT
F1100BB01 FILTER GEN PURPOSE/SGL PHASE 1A
F11010102 BUTTON CAP WHITE
F1200DD30 FILTER POWER LINE EMI 30A SCREW
相关代理商/技术参数
EWN2660-0G 功能描述:DC/DC转换器 RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
EWP201-011 制造商:JVC Worldwide 功能描述:ANTENNA WIRE
EWP-AA-0102-96S-ZZ-L 制造商:Finisar Corporation 功能描述:1X2 DROP, EWP SERIES, 50GHZ CHANNEL SPACING, LC CONNECTORS - Trays
EWP-AA-0104-96F-ZZ-L 制造商:Finisar Corporation 功能描述:1X4 EWP4, FLEXGRID, C-BAND, LC CONNECTORS - Bulk
EWP-EK-AA 制造商:Finisar Corporation 功能描述:EWP EVALUATION BOARD - Boxed Product (Development Kits) 制造商:Finisar Corporation 功能描述:KIT EVAL EWP PWR/SER INTERFACE
EWR1601-0 功能描述:DC/DC转换器 DIN Rail 120W (24.7V) RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
EWR1601-0G 功能描述:DC/DC转换器 RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
EWR-16-17 制造商:Middle Atlantic Products 功能描述: